Technical
Model : | BS 40 | BS 42 A | BS-44 | BS-44 B | BS-46 | BS-50 |
Mechanical Characteristics | ||||||
Dimensions (mm x mm ) | 635 x 1245 | 635 x 1245 | 635 x 1245 | 652 x 1262 | 635 x 1245 | 635 x 1245 |
Weight ( Kg ) | 13.50 | 13.50 | 13.50 | 15.00 | 13.50 | 13.50 |
Electrical Characterristics | ||||||
Maximum power ( Wp ) | 40 | 42 | 44 | 44 | 46 | 50 |
Maximum power voltage ( V ) | 44.80 | 45.80 | 46.90 | 46.90 | 70.30 | 70.90 |
Maximum power current ( A ) | 0.93 | 0.96 | 0.99 | 0.99 | 0.66 | 0.71 |
Open circuit voltage ( V ) | 62.20 | 62.40 | 62.60 | 62.60 | 93.00 | 93.40 |
Short circuit current ( A ) | 1.14 | 1.16 | 1.17 | 1.17 | 0.82 | 0.86 |
Maximum system voltage ( V ) | 600 | *1000 | 1,000 | 1,000 | *1000 | *1000 |
Temperature Coefficients : | ||||||
Maximum power ( W ) | – 0.2% / oC | |||||
Open circuit voltage ( V ) | – 0.2957% / oC | |||||
Short circuit current ( A ) | – 0.0395% / oC |
Measurements made under the standard test conditions ( STC ) :
– Irradiance of 1,0000 W / m2
– Spectrum of Air Mass 1.5
– Module temperature of 25 oC
– BS 42 A , BS-44 , BS-44 B , BS-46 , BS-50 : Compliance with IEC Standard and under – testing at TUV , VDE , UL
*For UL Standard the maximum system voltage shall be 600 V.